The AN-307 LoRaWAN Siren makes light and sound to tell the guard management there is an alert. It supports standard LoRaWAN protocol. It has high detection accuracy. With a durable shell, it has a long-life span.
Feature
Support LoRaWAN 1.0.2/ 1.0.3
Frequency: CN470/AS923/ EU868/US915/AU915 optional
Application
Typically installed on wall. For example, you can get an alert on the management
platform immediately if a window open when you go to bed, or if you leave home
without closing the back door.
Specification
Function
|
Item
|
Description
|
Wireless performance
|
Antenna
|
Built-in LoRa Antenna
|
Data transmission rate
|
300bps-5.4Kbps
|
Frequency
|
CN470-510MHz
EU863-870MHz
US902-928MHz
AS923MHz
AU915-928MHz
KR920-923MHz
|
Maximum Tx power
|
20dBm
|
Rx sensitivity
|
-141dBm (SF=12)
|
Function
|
Light alarm
|
120 times/minute±10%
|
Siren volume
|
≥110dB
|
Flash energy
|
≥1.2WS
|
Sounds optional
|
Police sound effect; Fire engine
sound; Ambulance sound
optional
|
Ambient
|
Working temperature
|
-10℃- +50℃
|
Working humidity
|
5%-95% (no condensing)
|
Electric parameter
|
Power supply
|
DC12V
|
Standby electric current
|
<=28mA
|
Tx current
|
<=125mA
|
Physical parameter
|
Dimension
|
125mm*125mm*47mm
|
Install and wiring
1. Before installation, please check if the device intact with full accessory kits.
2. The alarm shall be installed on the wall. It is recommended to be fixed as 0.2m away from the ceiling.
3. During installation, fix the device mounting plate to the embedded 86H50 junction box into the wall with two screws.
4. Connect the cable to the corresponding terminal through the inlet hole of the device base. Then clip device with the bottom and put it on the base plate. Gently press the top of the device to fix.
5. Gently press the top or bottom of the device for disassembling.
6. The power cord uses BV wire with the cross-sectional area as ≥1.5mm2.
How to work
After a sensor triggered, it sends alarm data to management platform. After receiving the data, it sends messages to AN-307. Then AN-307 generates sound and light as a warn for prompt alarm management. Once the alarm disarming, it makes sounds and light for 10 seconds. Installation method: wall-mounted, track-mounted.
Useful Link:
Wireless configuration tool
User Manual
CP210x_Windows_Drivers(for wireless configuration tool)
How to install CP210x driver for wireless configuration tool
and the interface of Winext manage APP
serialport-win32-x64(v1.0.8)Winext manage APP